  figure 1. agilents new pc-hosted logic analyzer offers intuitive and transportable measurement capability. the agilent technologies logic wave E9340A logic analyzer offers design engineers a low-cost, transportable debug tool that is easy to set up and use. with the amazing price/per- formance of logic wave, designers can afford to use a personal analyz- er to conduct basic measurements rather than wait for the lab analyzer to become available. logic wave is pc-hosted, making it an ideal tool for cramped work- spaces. the intuitive, single window user interface runs as a microsoft windows 95/98/nt application on any pentium or better pc and does not require a dedicated pc. run it on a laptop and the entire system is completely portable. software and software updates are available at no cost on the internet. download the user interface now and try it yourself at: www.agilent.com/find/logicwave or request the logic wave product cd number 5968-6655e. model agilent technologies logic wave (E9340A) state/timing channels 34 maximum state clock 100 mhz maximum timing sample-rate 250 mhz memory depth 128k timing, 64k state user interface windows 95, 98, 2000 (professional and me), nt 3.1, and nt 4.1, pc-hosted (runs as an application on any pentium or better, desktop or laptop) ?ydiwyc?timing trigger what you draw is what you capture?visual timing trigger events printers shared with the host pc - can print to any local or network printer supported by the pc probing agilent patented, 100k ? , 1.5 pf dimensions 11.5?x 9?x 2.5?(29.1 x 22.8 x 6.3 cm) weight 4.5 pounds (2.1 kg) i/o ports enhanced parallel connection to pc for fast display update rates, trigger in/out bnc agilent technologies logic wave E9340A pc-hosted logic analyzer technical data microsoft is a u.s. registered trademark of microsoft corp. pentium is a u.s. registered trademark of intel corporation. affordable and user-friendly logic analysis
2 figure 2. logic wave graphical user interface (timing measurement) measurement start and stop two levels for triggering on pulse durations or sequential events draggable x marker trigger marker draggable o marker easy trigger setup physical channel tool tip expanding/collapsing buses drag and drop signals into bus color-coded signals and probes activity indicators drag area to zoom agilent technologies logic wave E9340A
3 figure 3. logic wave graphical user interface (state measurement) easy trigger setup trigger measurement start and stop expanding/collapsing buses additional view of captured data status bar color-coded signals and probes time information add ?r conditions state number draggable o marker draggable x marker agilent technologies logic wave E9340A
4 165.10 mm 6.50 in. 63.5 mm 2.50 in. cable egress 241.30 mm 9.50 in. 63.50 mm 2.50 in. 292.10 mm 11.50 in. power plug power switch analyzer cables bnc kensington key lock multi-use port* parallel port figure 4. logic wave dimensions and weight f igure 5. diagram of logic wave rear panel weight: 4.5 lbs (2.1 kg) additional features: zoom box to zoom in on part of a waveform, click and drag a box around the area of interest. multiple group into bus ? in addition to dragging-and-dropping individual channels into a bus, you can also select multiple channels. use ctrl+mouse, right click, and select "group into bus" from the menu. physical channel tool tip after renaming signals, you can hold the cursor over the new name and the location (pod and channel numbers) of the signal will appear. color-coded signals and probe leads ? colored activity indica- tors on screen correspond to the color of the equivalent channel on the general-purpose lead set. external trigger for scope logic wave can be used to trigger an oscilloscope by connecting the portout bnc to the portin of the oscilloscope. capture screen shot ? use ctrl+alt+printscrn to capture a logic wave screen, as you would with any other windows program. export data to microsoft excel ? an ascii version of logic wave files can be imported into excel for data analysis. off-line analysis ? data files can be viewed on any machine that has the software interface installed, regardless of whether a logic analyzer is connected or not. agilent technologies logic wave E9340A * currently unimplemented usb port*
5 agilent technologies logic wave E9340A specifications and characteristics timing analysis sample period accuracy ?.01% channel-to-channel skew 2 ns typical, 3 ns max timing interval accuracy ?sample period accuracy + channel-to- channel skew + 0.01% of time interval reading) state analysis setup/hold 1 4.0/0 ns fixed minimum state clock pulse width 3.5 ns time tag resolution 8 ns or 0.1% (whichever is greater) maximum time count 34 seconds between states clock qualifiers setup/hold 4.0/0 ns fixed triggering sequencer speed 125 mhz maximum state sequence levels 3 timing sequence levels 2 port in delay 35 ns between rising edge on port in bnc and dont care logic analyzer trigger port out delay 120 ns between logic analyzer trigger and rising edge on port out bnc probes input resistance 100 k ? ?% parasitic tip capacitance 1.5 pf minimum input voltage swing 500 mv peak-to-peak threshold accuracy ?100 mv + 3% of threshold setting) threshold range ttl, ecl, -6.0 v to + 6.0 v in 50 mv increments maximum input voltage 40 v peak operating environment temperature instrument: 0?c to 55? c (+32?f to 131?f) disk media: 10?c to 40?c (+50?f to 104?f) humidity up to 95% relative humidity at 40?c altitude 4,572 m (15,000 ft) data storage supported file formats for screen shots use ctrl + alt + prtscrn to create bitmap configuration and data files encoded in binary format (stored to or loaded from host pc); can export acquired data to an ascii formatted file. 1 minimum setup/hold time specified for single-clock, single-edge acquisition. for single-clock, multi-edge or multi-clock, multi-edge acquisition, add 1.0 ns to setup time.
6 the logic wave probe cables are compatible with a wide range of probing adapters and accessories available from agilent technologies and its channel partners. see probing solutions for agilent technologies logic analysis systems (pub. no. 5968-4632e) for more information on probing. figure 8. ultra-fine pitch surface mount device clips figure 9. wedge probe adapters for qfp package figure 6. general-purpose lead set probing alternatives probing the device under test is potentially one of the most difficult and certainly one of the most important tasks in debugging a digi- tal design. that is why agilent technologies provides a wider vari- ety of probing solutions than any- one else in the industry ?each with a different set of advantages particular to a given situation. we like to think of it as helping you get your signals off to a great start. probing alternative advantages limitation _____ ________________________________________________________________ general-purpose most flexible method. works in can be cumbersome lead sets and surface conjunction with smd clips and wedge when connecting mount ic clips adapters listed below. included with a large number (figure 6 & 7) logic analyzer purchase. of channels. _________________________________________________________________________________________ ultra-fine pitch surface smallest ic clips in the industry to date same as above plus mount device clips (down to 0.5 mm). works with both logic small incremental (figure 8) analyzer and scope probing systems. cost. _________________________________________________________________________________________ wedge probe adapter compressible dual conductors between same as above plus for qfp packages adjacent ic legs make 3-16 adjacent signal small incremental (figure 9) leads available to logic analyzer and cost. scope probing systems. _________________________________________________________________________________________ direct connection to very reliable and convenient probing requires advance device under test via system when frequent probing planning to integrate built-in connectors connections are required (manufacturing into design process. (figure 10 & 11) or field test for example). connectors moderate (normal can be located at optimal position in density) to the device under test. significant (high density) incremental cost. replacement part numbers for logic analyzer probes ____________________________________________________________________________ 5959-9333 five gray probe leads 5959-9334 five short ground leads 01650-61608 16-channel probe lead set 5090-4356 surface-mount ic clips (package of 20) 5959-0288 throughhole ic clips (package of 20) figure 7. surface mount ic clip probing alternatives for logic analyzers 10467-68701 0.5 mm smd clips (qty 4) e2613a wedge, 0.5mm, 3 signal (qty1) e2613b wedge, 0.5mm, 3 signal (qty 2) e2614a wedge, 0.5mm, 8 signal (qty 1) e2643a wedge, 0.5mm, 16 signal (qty 1) e2615a wedge, 0.65mm, 3 signal (qty1) e2615b wedge, 0.65mm, 3 signal (qty 2) e2616a wedge, 0.65mm, 8 signal (qty 1) e2644a wedge, 0.65mm, 16 signal (qty 1) e5346a high-density termination adapter e5346-44701 shroud for high-density termination adapter e5346-68701 mictor high-density connector (qty 5) 01650-63203 normal-density termination adapter 1251-8106 normal-density 20-pin connector
7 agilent e5346a high-density adapter cables probe cables from logic analyzer internal rc networks optional shroud (agilent part number e5346-44701) mictor (agilent part number e5346- 68701) figure 11. high-density direct connection solution figure 10. normal-density direct connection solution agilent 01650-63203 termination adapter related literature publication publication title description number logicwave user interface software product cd-rom 5968-6655e probing solutions for agilent technologies logic analysis systems product overview 5968-4632e product warranty logic wave is warranted against defects in materials and workmanship for a period of three years from date of shipment. some newly manufactured agilent technologies products may contain remanufactured parts, which are equivalent to new in performance. if you send notice of defects during the warranty period, agilent will either repair or replace hardware products that prove defective. E9340A logic wave 34-channel, pc-hosted logic analyzer option 001 quick reference card and target board ordering information
agilent technologies?test and measurement support, services, and assistance agilent technologies aims to maximize the value you receive, while minimizing your risk and problems. we strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. our extensive support resources and servic- es can help you choose the right agilent products for your applications and apply them successfully. every instrument and sys- tem we sell has a global warranty. support is available for at least five years beyond the production life of the product. two concepts underlie agilent's overall support policy: "our promise" and "your advantage." our promise our promise means your agilent test and measurement equipment will meet its adver- tised performance and functionality. when you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. when you use agilent equip- ment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. many self-help tools are available. your advantage your advantage means that agilent offers a wide range of additional expert test and measurement services, which you can pur- chase according to your unique technical and business needs. solve problems effi- ciently and gain a competitive edge by con- tracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on- site education and training, as well as design, system integration, project manage- ment, and other professional engineering services. experienced agilent engineers and technicians worldwide can help you maxi- mize your productivity, optimize the return on investment of your agilent instruments and systems, and obtain dependable measure- ment accuracy for the life of those products. for more assistance with your test & measurement needs go to: www.agilent.com/find/assist or contact the test and measurement experts at agilent technologies (during normal business hours) united states: (tel) 1 800 452 4844 canada: (tel) 1 877 894 4414 (fax) (905) 206 4120 europe: (tel) (31 20) 547 2000 japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 latin america: (tel) (305) 267 4245 (fax) (305) 267 4286 australia: (tel) 1 800 629 485 (fax) (61 3) 9272 0749 new zealand: (tel) 0 800 738 378 (fax) 64 4 495 8950 asia pacific: (tel) (852) 3197 7777 (fax) (852) 2506 9284 product specifications and descriptions in this document subject to change without notice. copyright ? 2000 agilent technologies printed in usa 11-00 5968-5560e


▲Up To Search▲   

 
Price & Availability of E9340A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X